Click here to return to the LAND home page
Click here to view this site in Chinese Cliquer ici pour visualiser le site en Français Zur deutschen Website Link al sito Italiano
Kliknij tutaj, aby zobaczyc ta strone po Polsku Pinche aquí para verlo en Español Click here to view this site in English (American)
spacer


Nitrogen Oxides - NO x

Nitrogen oxides measurement for environmental emissions monitoring applications

Your search for nitrogen oxides has brought you to LAND.
Refer to the Product Range table below to select the product most suitable to your application.

LAND has a comprehensive range of NOx analysers for total oxides of nitrogen (NOX) in emissions monitoring applications.

LAND can supply both portable and continuous nitrogen oxides monitors and analysers, for low and high temperature flue gas applications.

Importantly we measure NO and NO2 to produce the NOx reading. No NOx conversion or calculation methods are required.

Continuous monitors are available for stack mounting, using an extractive measurement technique.
  Quick Links  
  Product Range
Services and Support
News
Info for Download
Contact Us

 
   
  Product Selector  
 
Please select your gas from the list below.

 
     

Nitrogen Oxides (NOX) Measurement - Product Range
Product Name Lancom FGA 900 Series FGAII
Continuous Analyser  
Portable Analyser    
Emissions Compliance
Extractive Measurement
Measurement Range 0 - 1000 up to
0 - 5000 ppm
0 - 50 up to
0 - 2000 ppm
0 - 10 ppm up to
0 - 50, 000 ppm
Flue Gas Temperature Range up to 600°C
(Standard Probe)
up to 1700°C up to 1700°C
Product Approvals TÜV Tested US-EPA, TÜV, UK MCerts US-EPA, TÜV, UK MCerts
Other Gases Measured O2, NO, NO2, CO, H2S, CXHY, SO2, CO2 O2, NO, NO2, CO O2, NO, NO2, CO, SO2, CO2


Lancom III - Portable Combustion and Emissions Analyser for Nitrogen Oxides (NOX)
The Lancom III is a compact, portable combustion and emissions analyzer for checking or testing a boiler system or pollutant process. It can measure total Nitrogen Oxides by measuring both NO and NO2 plus up to 8 other gases simultaneously and a total of 17 different parameters. It is lightweight (about 6 kg / 15 lb) and is easy to carry around any plant. >>>

FGA 900 Series - Continuous, Extractive Nitrogen Oxides (NOX) Monitor
The FGA 900 series of continuous emissions monitors use dual sensor technology to measure the levels of Nitrogen Oxides (NOX) in a single compact unit by measuring both NO and NO2. >>>

FGAII - Continuous, Extractive, Stack Gas Emissions Analyser for Nitrogen Oxides (NOX)
The FGAII stack gas emissions analysers use advanced dual sensor technology to measure the levels of Nitrogen Oxides (NOX) by measuring both NO and NO2, plus up to 6 other gases in a single compact unit. The gas sampling is provided by the ChillerProbe - Advanced Stack Gas Sampling System >>>


Measurement Techniques  
In-situ measurement The sample gas is measured at the installation point; where a fast response measurement is normally required e.g. combustion control applications . The measurement can normally be termed hot and wet.
Extractive measurement The sample gas is removed from the process stream, and transported to a separate analyser system, The measurement can normally be termed cooled and dry.


 
Top of pageNitrogen Oxides (NOx) - Flue gas nitrogen oxides (NOx) measurement for continuous emissions monitoring