Sulphur Dioxide - SO 2
Sulphur dioxide measurement for environmental emissions monitoring applications
Your search for sulphur dioxide has brought you to LAND.
Refer to the Product Range table below to select the product most suitable to your application.
LAND has a comprehensive range of sulphur dioxide monitors and analysers for emissions monitoring applications. LAND can supply both portable and continuous sulphur dioxide monitors and analysers, for low and high temperature flue gas applications.
Continuous sulphur dioxide monitors are available for stack mounting, using an extractive measurement technique. |
|
|
Sulphur Dioxide Measurement - Product Range
| Product Name |
Lancom |
FGAII |
| Continuous Analyser |
|
 |
| Portable Analyser |
 |
|
| Emissions Compliance |
 |
 |
| Extractive Measurement |
 |
 |
| Measurement Range |
0 - 2000 up to
0 - 5000 ppm |
0 - 10 ppm up to 0 - 40, 000 ppm |
| Flue Gas Temperature Range |
up to 600°C (Standard Probe) |
up to 1700°C |
| Product Approvals |
TÜV Tested |
US-EPA, TÜV, UK MCerts |
| Other Gases Measured |
CO, O2, NO, NO2, NOX, H2S, CXHY, CO2 |
O2, NO, NO2, NOX,CO, CO2 |
Lancom III - Portable Combustion and Emissions Analyser for Sulphur Dioxide (SO2)
The Lancom III is a compact, portable combustion and emissions analyzer for checking or testing a boiler system or pollutant process. It can measure Sulphur Dioxide (SO2) plus up to 8 other gases simultaneously and a total of 17 different parameters. It is lightweight (about 6 kg / 15 lb) and is easy to carry around any plant. >>>
FGAII - Continuous, Extractive, Stack Gas Emissions Analyser for Sulphur Dioxide (SO2)
The FGAII stack gas emissions analysers use advanced dual sensor technology to measure the levels of Sulphur Dioxide (SO2)plus up to 6 other gases in a single compact unit. The gas sampling is provided by the ChillerProbe - Advanced Stack Gas Sampling System >>>
| Measurement Techniques |
|
| In-situ measurement |
The sample gas is measured at the installation point; where a fast response measurement is normally required e.g. combustion control applications . The measurement can normally be termed hot and wet. |
| Extractive measurement |
The sample gas is removed from the process stream, and transported to a separate analyser system, The measurement can normally be termed cooled and dry. |

|
|
|
|