| SPECIFICATIONS |
| Probe |
Material:
Detector:
Flue Gas Temperature:
Length:
Weight (Probe):
Weight (M'ting Tube) :
Mounting Flange:
|
Stainless steel
Pyrex glass with platinum electrodes
0 to 400 °C / 32 to 750 °F
1.2m / 4 ft standard
2.4 kg / 5.3 lb
3.9kg / 8.6lb
Land supplied |
| Electronic Control Unit (ECU) |
Electronics:
Selectable Display:
|
Microprocessor based
Sulphuric Acid Dewpoint Temperature, RBU,
Ambient Temperature, MMT, Current, SO3 |
Output:
Accuracy:
Operating Temperature:
|
2 current 4-20mA
(0 to 260 °C / 0 to 500 °F)
±2 °C / ±4 °F
0 to 50 °C / 32 to 120 °F |
Input Air Supply:
AC Supply:
|
3 litres/sec / 6 cfm
110/240V a.c. 50/60Hz |
Alarms / Relays:
Enclosure:
Weight:
Dimensions:
|
Maintenance / Fault
One common relay
IP65 / NEMA 4
18 kg / 38 lb
600 x 380 x 210mm /
23.6 x 15 x 8.3 inches |
| Air Flow Regulator and Detector Cleaning System (ACU) |
Enclosure:
Air Flow Rate:
Air Pressure:
Operating Temperature:
Water Flow Rate:
Water Pressure:
Dimensions:
Weight:
|
IP65 / NEMA 4
3 litres/sec / 6 cfm
60 to 100 psi / 4 to 7 bar
0 to 65 °C / 32 to 160 °F
4 litres/day maximum usage
20 psi / 1.4 bar
600 x 600 x 210mm /
23.6 x 23.6 x 8.6 inches
29.5 kg / 65 lb
|
Continuous Product Development may make it necessary to change these details without notice |