Stack Gas Emissions Analyser   Need more information?  
FGA II Logo - Stack Emissions Monitoring

The FGAII stack gas emissions analysers use advanced dual sensor technology to measure the levels of up to 7 pollutant gases in a single compact unit.

FGAII gas analysers carry a wide range of compliance and performance approvals including those from the US-EPA, UK MCERTS and German TÜV.

LAND’s measurement technique ensures stable long-term operation with high accuracy and very low drift. Engineered for ease of maintenance and packaged for the industrial environment, FGAII stack gas emissions analysers are simple to install and trouble-free in operation.


Click here for more information on EN14181 compliance





Stack Gas Emissions Analysers - Product Selection Table

FGAII stack gas emissions analyser










FGAII - stack gas emissions analyser

Quick Links
Stack gas emissions analysers

Continuous Emissions Monitoring Systems

Engineering Solutions for CEM/AMS Projects

Advanced Gas Sampling for FGAII

EN14181 - More Information

Gas Measurement Options Max. No. per analyser Measured NOx Min. Range Modbus Comms. Remote Diagnostics TÜV MCerts US-EPA Model
O2 CO NO NO2
NOx CO2 SO2
7 Y 0 - 10 ppm Y Y Y Y Y FGA II
O2 CO NO NO2 3 Y 0 - 50 ppm N N Y Y Y FGA 900 Series

Measurement Capability
FGA II Series stack gas emissions analysers can measure up to 7 gases in a single instrument.
 
Gases Measured and Calculated
Carbon Monoxide (CO)
Oxygen(O2)
Nitric Oxide (NO)
Nitrogen Dioxide (NO2)
Nitrogen Oxides (NOx) - calculated where NO2 sensor not fitted
Sulphur Dioxide (SO2)
Carbon Dioxide (CO2)
Further Information

English - 441KB
Last Modified (21/09/06)

Italiano - 128KB
Last Modified (23/01/04)

Français - 409KB
Last Modified (27/09/06)

Documentation format PDF - 4200 Chinese - 352KB
Last Modified (17/10/06)

Click here for our complete range of product and application support information.

 
Features and Benefits
Fully integrated system in a single compact box - up to 7 gases in a single analyser
Wide measurement range - from 0 - 10 ppm up to 0 - 50,000 ppm
Universally accepted, certified performance - complies with the latest monitoring standards
Simple, low maintenance - all maintenance carried out on-site
High measurement performance - ADST ultra-low drift measurement technology
Measured Total NOx (NO + NO2) - separate sensors for true NOx monitoring
Automatic calibration option - for continuous unattended operation in compliance monitoring applications
Simple installation - no need for expensive air-conditioned enclosures

Product Approvals

Environmental Protection Agency Approval Mcerts approval
TUV approval

TÜV approved to the 13th, 17th and 27th
BImSchV and TA Luft
MCerts certified Continuous Emissions Monitoring System
Meets the requirements of ISO 12039,
ISO 10849 & ISO 7935
Meets LCP and Waste Incineration
  Directives 2001/80/EC and 2000/76/EC
Meets EN 14181 QAL1 requirements for most processes
Meets the requirements for USEPA Part 60, 63 ,75, 266, 267 and 503 applications
Mexico INE-CENICA/OFICIO/128/2002 acceptance for continuous process emissions monitoring

Advanced Dual Sensor Technology
The FGAII continuous emissions monitor uses Advanced Dual Sensor Technology (ADST) to measure specific pollutant gasses. This technique ensures stable long-term operation with high accuracy and ultra-low drift. FGA series emissions analysers are simple to install and use, and trouble free in operation.

Click here for more details on Advanced Dual Sensor Technology (PDF 396 Kb)

True NOx measurement
The FGAII is designed for very low level NOx measurement. The analyser measures both NO and NO2 separately, these are combined to give a true NOx measurement output. The inherent problems with NO2 converters are therefore completely avoided.

NO Heated Sample Lines
Heated sample lines are not required in most applications. The sample gas is cooled and dried inside the ChillerProbe - advanced flue gas sample system.
SPECIFICATIONS
 Measurement Ranges
Technique: Advanced Dual Sensor Technology (ADST)
 CO Ranges: 0 - 10 ppm up to 0 - 40 000 ppm (4 %)
 NO Ranges: 0 - 10 ppm up to 0 - 50 000 ppm (5 %)
 NO2 Ranges: 0 - 10 ppm up to 0 - 1 000 ppm (0.1 %)
 SO2 Ranges: 0 - 10 ppm up to 0 - 10 000 ppm (1 %)
 CO2 Ranges: 0 - 3 Vol. % up to 0 - 100 Vol. %
 Resolution: 0.1 ppm (CO, NO, NO2 & SO2); 0.1 % (CO2)
 Linearity: < 2 % of range
 Zero drift: < 2 % of range per month
 Span drift: < 2 % of range per month
 O2 Ranges: 0 - 5 Vol % to 0 - 25 Vol %
 Resolution: 0.01 Vol %
 Linearity: < 0.2 Vol %
 Zero drift: < 0.2 Vol % per month
 Span drift: < 0.2 Vol % per month
 Calibration
 Calibration method: Manual or Automatic
2 or 3 point span calibration; zero calibration
Automatic Gas Selection (option)
Microprocessor controlled
 Display:
 Type: LCD + LED backlight
 Size: 125 x 35 mm / 5 x 1.5 in
 Parameters: 5 function keys; alphanumeric and graphic
 Outputs/Inputs
 Analogue outputs: Isolated current loops
One per gas (plus total NOx if applicable)
expandable up to 32, in multiples of 8
0,2 or 4 to 10 or 20 mA
 Relays outputs: One per gas (plus total NOx if applicable) plus System OK, Warning, Calibrating, Maintenance, expandable up to 20, in multiples of 5, including calibration gas status relays
 Relay rating: Isolated change-over contacts rated 0.5 A @ 125 V a.c.;
1 A @ 30 V d.c.
 Digital Inputs: Calibrate, Standby, Optional fuel selection
Volt-free contact closure or 5 - 24 V d.c.
 Analogue inputs: Isolated current loops
Up to 16, in multiples of 8, active or passive
0, 2 or 4 to 10 or 20 mA
 Communications: RS485 Modbus serial digital data bus ( 2 or 4 wire)
 Environmental
 Enclosure: Stainless steel sealed to the requirements of
IP65 / NEMA 4X
 Operating (ambient)
  temperature:

-40 &de°C / -40 °F to 104 °F standard
-40 &de°C / -40 °F to 122 °F most measurement ranges
 Compliance
 Measurement
  standards:

Meets the requirements of ISO 12039, ISO 10849 & ISO 7935
Meets LCP & Waste Incineration Directives 2001/80/EC and 2000/76/EC
Meets EN14181 QAL 1 requirements for most processes
Meets the requirements for USEPA Part 60, 63, 75, 266, 267 & 503 applications
 Approvals: TÜV approved to the 13th, 17th & 27th BImSchV and TA Lüft
MCerts certified to Performance Standards for Continuous Emissions Monitoring Systems (Nov.1998)
 Electrical Safety: Conforms to EN-61010-2
 EMC: Conforms to EN61326 (Industrial)
 Power
 Power Supply: 100 to 120 V a.c. or 200 to 240 V a.c., 50 - 60 Hz
 Power Consumption: Analyser: 600 W
Anti-freeze sample line: 15 W / m (5 W / ft)
 Note: Additional power and air required for ChillerProbeTM
 Gas & Air Requirements
 Instrument air
  For zero calibration:
4 bar / 60 psi min clean,dry and solvent free
1 bar / 15 psi; 10 l/min / 0.4 cfm maximum
 Calibration gas
  (recommended):
1 bar / 15 psi; 2 l/min / 0.08 cfm
10 litres / 0.35 cu. ft. (16 litres / 0.56 cu. ft. for NO2) per calibration approx.
 Calibration gas type: Specific to each gas type and measurement span
 Dimensions
 (H x W x D)

Single stream: 600 x 600 x 420 mm / 24 x 24 x 17in
Twin stream: 870 x 600 x 420 mm / 34 x 24 x 17 in
 Weight: Single stream: 50 kg /110 lb
Twin stream: 73 kg / 161 lb
 Options
 Automatic Calibration
 Twin Stream Option
 Remote Diagnostics

Continuous Product Development may make it necessary
to change these details without notice


Engineered for the future
Excellent low level emissions capability
Wide range of sensor options operating in a controlled environment, to provide the precision necessary for the level measurements required by legislative limits
Wide ambient temperature range without air conditioner
Measurement sensors are temperature controlled
Heated sample line not required in most applications
Sample gas is cooled and dried inside the probe
Suitable for outdoor installation without a protective shelter
Weatherproof, stainless steel NEMA 4X / IP65 enclosure
Low maintenance requirement
A complete service takes less than an hour.
Recover lost emissions data and assist fault diagnosis
Internal data log can recall lost emissions data where a DAS fails, plus store vital instrument operating history to assist fault diagnosis
Easy to install anywhere
The analyser is only 600 mm /24 “square and weighs less than 50 kg / 110 lb (single stream version)

If you would like more detailed product information please use the Further Information form.

 
Top of pageFGA II Series stack gas emissions analysers - Information updated: 17-Oct-2006
Copyright © 1998-2006   Land Instruments International.   All rights reserved.   Combustion Site Map