Profile - a high speed signal sent to the data acquisition system for data logging |
 |
Peak - the highest temperature on the blade array |
 |
Average - the average temperature of the blade array |
 |
Average Peak - the average of the highest temperature of each of the blades |
 |
Continuous on-line measurement of individual blade condition |
 |
Increased efficiency through improved engine firing rate |
 |
Detection of blocked cooling channels |
 |
Reliable, accurate blade row temperature |
 |
Early warning of potential blade failure caused by over-temperature operation |
 |
Continuous monitoring of blade coating condition |
 |
Blade Sentry pyrometer meets ATEX Directive 94/9/EC; coding CE Ex II 3 G T6 |