| SYSTEM 4 INFRARED THERMOMETER SIGNAL PROCESSORS |
| |
LANDMARK® infrared thermometer signal processors are designed to produce the process control variables you need from ANY of the SYSTEM 4 infrared thermometers. With this total compatibility, you are free to choose a processor to give the features and performance that are best suited to your application.
All SYSTEM 4 processors and thermometers are calibrated individually to guarantee interchangeability and hence easy maintenance for many years.
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
LANDMARK® GRAPHIC
a high precision, multi function, intelligent thermometer signal processor >>> |
|
LANDMARK® CLASSIC
a lower cost, modular thermometer signal processor >>> |
|
LANDMARK® for Profibus
a high precision, digital, DIN-rail mounted thermometer signal processing unit >>> |
|
LANDMARK® TECHNIC
a high precision, DIN-rail mounted, intelligent digital thermometer signal processor >>> |
|
LANDMARK® BASIC
a simple DIN-rail mounted thermometer signal processing unit >>>
|
|
 |
A Literature download on System 4 Processors is available
Last Modified (08/07/03) (1511KB). |
Landmark® is a registered Trademark of Land Instruments International |
|
|
|
|
|
|
|
| LANDMARK GRAPHIC |
| |
 |
|
LANDMARK® GRAPHIC is a high precision, multi function, intelligent infrared thermometer signal processor with graphical display. Two versions are available: a single channel and a multiple channel processor.
The multiple channel version can be configured with up to four different thermometers. A simple to use multi-language menu enables the user to set-up the thermometer and process variables.
LANDMARK® GRAPHIC provides a complete range of thermometer signal conditioning functions including: peak picker, averager, track and hold, high/low alarms and 0 or 4 to 20mA and 1mV/° outputs from each thermometer channel.
Temperature is displayed as a deviation chart, line chart, numeric or mixed display.
Optional serial RS232C/RS485A communications is also available.
|
| |
|
|
A new math function is available which simultaneously computes and outputs two additional values including: maximum, minimum, mean, difference, range and expanded span. Typical examples include: monitoring the temperature uniformity across a web or strip using an array of 4 thermometers; expanded span which combines the minimum and maximum temperature ranges of up to 4 different thermometers; and difference where two thermometers are monitoring the same target spot.
| Summary Specification |
| Accuracy: |
0.12% reading |
| Outputs: |
0 or 4 to 20mA and 1mV/° |
| Peak Picker: |
0, 0.25, 0.5, 1, 2, 4, 8, 16, 32, 64, 128, 256, 512°/s decay rate |
| Averager: |
0, 0.25, 0.5, 1, 2, 4, 8, 16, 32, 64, 128, 256, 512s time constant |
| Track and Hold: |
10ms response time |
| Alarms: |
High or low |
| VERSION WITHOUT A SYSTEM CARD |
| LMG-M 1000-0 |
Single Channel LMG |
| LMG-M 1100-0 |
Twin Channel LMG |
| LMG-M 1110-0 |
Three Channel LMG |
| LMG-M 1111-0 |
Four Channel LMG |
| |
|
| VERSIONS WITH A SERIAL COMMUNICATIONS CARD |
| LMG-M 1000-1 |
Single Channel LMG with RS232C/RS485A Serial Comms |
| LMG-M 1100-1 |
Twin Channel LMG with RS232C/RS485A Serial Comms |
| LMG-M 1110-1 |
Three Channel LMG with RS232C/RS485A Serial Comms |
| LMG-M 1111-1 |
Four Channel LMG with RS232C/RS485A Serial Comms |
| |
| VERSIONS WITH A SERIAL COMMUNICATIONS AND MATH CARD |
| LMG-M 1100-2 |
Twin Channel LMG with RS232C/RS485A and Math Card |
| LMG-M 1110-2 |
Three Channel LMG with RS232C/RS485A and Math Card |
| LMG-M 1111-2 |
Four Channel LMG with RS232C/RS485A and Math Card |
| |
| LANDMARK GRAPHIC ACCESSORIES & UPGRADES |
| LANDMARK Processor Protection Cover |
| LMG RS232C/RS485A Serial Comms Upgrade Kit (Complete with Back Panels) |
| LMG RS232C/RS485A Serial Comms and Math Upgrade Kit (Complete with Back Panels) |
| LMG RS232C/RS485A Software Upgrade Kit (To latest version of standard production software) |
| LMG I/O Channel Upgrades |
|
|
|
| LANDMARK CLASSIC |
 |
| |

|
|
LANDMARK® CLASSIC is a lower cost, modular infrared thermometer signal processor, providing a large digital display of temperature, emissivity/non greyness and alarm settings.
LANDMARK® CLASSIC System 4 thermometer provides a 4 to 20mA output for monitoring, recording or control. Optional plug-in time functions - either peak picker or averager - and alarm modules maximize the capabilities and flexibility of the system.
|
| Summary Specification |
| Accuracy: |
0.2% reading |
| Peak Picker (optional): |
0.05 to 25% of span/s |
| Averager (optional): |
0.1 to 60s |
| Alarms (optional): |
High or low |
| PROCESSOR TYPE |
ALARM 1 |
ALARM 2 |
TIME FUNCTION |
| LMC-0-0-0 |
- |
- |
- |
| LMC-A-0-0 |
YES |
- |
- |
| LMC-A-A-0 |
YES |
YES |
- |
| LMC-0-0-P |
- |
- |
PEAK PICKER |
| LMC-0-0-A |
- |
- |
AVERAGER |
| LMC-A-0-P |
YES |
- |
PEAK PICKER |
| LMC-A-0-A |
YES |
- |
AVERAGER |
| LMC-A-A-P |
YES |
YES |
PEAK PICKER |
| LMC-A-A-P |
YES |
YES |
AVERAGER |
OPTIONS
The LANDMARK CLASSIC Processor type LMC-0-0-0 can be expanded to take up to 2 alarm cards and one time function - either a Peak Picker or an Averager
ACCESSORIES
LANDMARK Processor Protection Cover
|
|
|
| LANDMARK PROFIBUS |
 |
| |
|
|
 |
|
LANDMARK® for Profibus is a high precision, digital, DIN-rail mounted signal processing unit, providing economic integration of any System 4 thermometer within a Profibus network - ideal for both OEM and end user applications.
LANDMARK® for Profibus (LMP) is an intelligent microprocessor-based thermometer signal processor, designed for the ultimate in process temperature monitoring at low cost.
A complete range of thermometer signal conditioning functions is provided including: peak picker, averager, track and hold, and alarm outputs.
As well as its standard Profibus DP interface, LMP also provides additional analog connectivity for supplementary process integration via a 0 or 4 to 20mA output with user-selectable span, Hi/Lo alarm contacts and external control of peak-picker reset or track & hold reset via customer contact closure.
|
| FEATURES |
 |
Profibus compatibility and connectivity |
 |
Standard DIN-rail, back of panel mounting |
 |
Time Functions - average, peak picker and track and hold as standard |
 |
Industry standard 0 or 4 to 20mA output |
 |
Emissivity/non-greyness adjustment |
 |
Alarm ready output |
 |
Optional LANDMARK indicator (LMi) and power supply (DPU) are also available |
 |
A Literature download on this product is available here - Last Modified (27/06/05) (144KB). |
|
|
|
| LANDMARK TECHNIC |
 |
| |
|
|

|
|
LANDMARK® TECHNIC is a high precision, DIN-rail mounted, intelligent digital processor.
| Features |
 |
adjustable emissivity/non-greyness |
 |
peak picker |
 |
averager |
 |
track and hold |
 |
alarm and 4 to 20 mA outputs |
 |
RS232C serial communications for set up via a PC |
|
| Summary Specification |
| Accuracy: |
0.1% reading |
| Output: |
0 to 20mA or 4 to 20mA |
| Peak Picker: |
0.25°/s to 512°/s |
| Averager: |
50ms to 512s |
| Track and Hold: |
10ms response time |
| Alarms: |
High or low |
 |
A Literature download on this product is available here - Last Modified (24/07/02) (64KB). |
|
|
|
| LANDMARK BASIC |
 |
| |
|
|

|
|
LANDMARK® BASIC is a simple back-of-panel DIN-rail mounted signal processing unit designed for system builders and OEM's.
Features include; adjustable emissivity/non-greyness, averager and peak picker with remote reset.
|
| Summary Specification |
| Accuracy: |
0.4% reading |
| Output: |
4 to 20mA |
| Peak Picker: |
1 to 5000% of span/s |
| Averager: |
175ms to 4s |
|
|
|
DIN-RAIL MOUNTED POWER SUPPLY UNIT
 |
|
The optional DIN-rail mounted power supply unit DPU provides the d.c. voltage which the Landmark Technic and Basic requires. |
LANDMARK - LMi
 |
|
An optional digital indicator provides a temperature display for the Landmark Basic. LMi is 1/8 DIN size with 14.2mm/0.55in display and dual hi/lo alarm outputs. |
If you would like more detailed product information please use the Further Information page.
|
|
|
Copyright © 1998-2006 Land Instruments International All rights reserved Infrared Site Map Information updated:
19-Jan-2006
|
|
|
|
|
|
|
|